What are the Common Flammability and Flame Retardants Standards applied on Tarpaulin?

What are the Common Flammability and Flame Retardants Standards applied on Tarpaulin?

What are the Common Flammability and Flame Retardants Standards applied on Tarpaulin?
How many different kind of common Flame Retardants Testing Standard are used worldwide?
No Testing Standard Descriptions
1 NFP92-507  
2 EN13501-1  
3 DIN4102-1 Fire behaviour of building materials and elements, Part 1: Classification of building materials requirements and testing.
4 CSFM T19  
5 ASTM E84  
6 BS7837  
7 BS5867  
8 AS/NZS 1530.3  
9 AS/NZS 3837  
10 ISO 6941:2003  
ASTIM E84 – Upholstered Walls 
Purpose: Rates flame spread and smoke development of interior finish building materials. 
Method: As application dictates (wrapped panels, glued fabric, etc.) samples are laid in 25’ tunnel and lit aflame at one end. 
Test: Measures how far and fast flames travel and the amount of smoke that develops. 
Association for Contract Textiles (ACT) Recommendation: Flame spread of 25 and smoke dev. of 450 or less for Class 1/A 

Notes: This is usually considered to include any items that are a part of the structure.

For products that pass these criteria: 
Class A, Flame Spread 1-25, Smoke Developed Less than or equal to 450 
Class B, Flame Spread 26-75, Smoke Developed Less than or equal to 450 
Class C, Flame Spread 76-200, Smoke Developed Less than or equal to 450. 

Please note, this test is comparable to UL 723, ANSI/NFPA No 255, and UBC No. 8-1
NFPA 701
The National Fire Protection Association (NFPA) has a book of guidelines for testing the flammability of objects. In many states, it is required for many fabrics used in public spaces to be flame retardant. A test known as NFPA 701 is conducted to demonstrate how textiles such as those found in canopies react when put on fire. What is observed is how much the fabric resists the flame after 12 seconds. What is measured following that is the size of the flame, the char length, and if the fabric continues to burn. If a fabric has a char length of smaller than 6.5 inches, an after-flame of less than two seconds, and it does not continue to burn after falling to the ground of the testing chamber, the fabric passes and is certified as flame retardant.

Test Method 1 
1) Fragments or residues of specimens that fall to the floor of the test chamber shall not continue to burn for more than an average of 2 seconds per specimen for the sample of 10 specimens. 
2) The average weight loss of the 10 specimens in a sample shall be 40 percent or less. 

Test Method 2 
1.Performance Criteria. 
1) When any specimen continues flaming for more than 2 seconds after the test flame is removed from contact with the specimen, the material shall be recorded as having failed the test. 
2) When the length of char of any individual folded specimen exceeds 1050 mm (41.3 in.), the material shall be recorded as having failed the test. 
3) When the char length of any single flat specimen exceeds 435 mm (17.1 in.), the material shall be recorded as having failed the test. 
4)When at any time during or after the application of the test flame, any portions or residues of the material being tested break or drip from the specimen fall to the floor of the test apparatus, and continue burning for more than 2 seconds after reaching the floor of the test apparatus, the material shall be recorded as having failed the test.
CPAI-84
This is a test to evaluate the flame resistance of fabrics found specifically in tents. CPAI-84 also gives certification and performance criteria to test suppliers. What is analyzed is how the fabric is resistant to fire depending on char length and how much mass was lost from burning. This test, however, does not determine whether or not a fabric is flame retardant. CPAI-84 was conceptualized in 1976 to reduce the likelihood of fires in paraffin-coated tents, such as those associated with circuses and fairs. This standard, however, is considered outdated and has not been revisited in over two decades. Since that time, very much has changed in the way textiles and fabrics for tents and canopies have been created. Both CPAI-84 and NFPA 701 are standards that assess flame-resistant properties of fabrics. While CPAI-84 is a standard made exclusively for materials in tents, NFPA 701 is a more general method of testing fabrics.